SCHEDULE 2TESTING METHODS

PART IImethods for the isolation ofsalmonella

Control Tests23

10 gram ± 1 gram portions of the rendered animal protein shall be placed aseptically in each of two sterile containers containing 90 ml ± 1 ml Buffered Peptone Water (BPW)25 and mixed thoroughly until the samples are evenly suspended.