1. The method allows the specific migration of lead and/or cadmium to be determined.
2. The determination of the specific migration of lead and/or cadmium is carried out by an instrumental method of analysis that fulfils the performance criteria of paragraph 4.
3.—(1) All reagents must be of analytical quality, unless otherwise specified.
(2) Where reference is made to water, it shall always mean distilled water or water of equivalent quality.
(3) 4% (v/v) acetic acid, in aqueous solution: add 40 ml of glacial acetic acid to water and make up to 1000 ml.
(4) Stock solutions: prepare stock solutions containing 1000 mg/litre of lead and at least 500 mg/litre of cadmium respectively in a 4% acetic acid solution, as referred to in sub-paragraph (3).
4.—(1) The detection limit for lead and cadmium must be equal to or lower than—
(a)0.1 mg/litre for lead; and
(b)0.01 mg/litre for cadmium,
where the detection limit is defined as the concentration of the element in the 4% acetic acid solution, as referred to in paragraph 3(3), which gives a signal equal to twice the background noise of the instrument.
(2) The limit of quantification for lead and cadmium must be equal to or lower than:
(a)0.2 mg/litre for lead; and
(b)0.02 mg/litre for cadmium.
(3) Recovery: the recovery of lead and cadmium added to the 4% acetic acid solution, as referred to in paragraph 3(3), must lie within 80-120% of the added amount.
(4) Specificity: the instrumental method of analysis used must be free from matrix and spectral interferences.
5.—(1) Preparation of the sample—
(a)the sample must be clean and free from grease or other matter likely to affect the test;
(b)wash the sample in a solution containing a household liquid detergent at a temperature of approximately 40 °C. Rinse the sample first in tap-water and then in distilled water or water of equivalent quality. Drain and dry so as to avoid any stain. The surface to be tested is not to be handled after it has been cleaned.
(2) Determination of lead and/or cadmium—
(a)the sample thus prepared is tested under the conditions laid down in Schedule 1;
(b)before taking the test solution for determining lead and/or cadmium, homogenise the content of the sample by an appropriate method, which avoids any loss of solution or abrasion of the surface being tested;
(c)carry out a blank test on the reagent used for each series of determinations;
(d)carry out determinations for lead and/or cadmium under appropriate conditions.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Executive Note sets out a brief statement of the purpose of a Scottish Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Scottish Statutory Instrument accessible to readers who are not legally qualified and accompany any Scottish Statutory Instrument or Draft Scottish Statutory Instrument laid before the Scottish Parliament from July 2005 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: