xmlns:atom="http://www.w3.org/2005/Atom"

SCHEDULE 3Overall and Specific Migration Testing Using Food Simulants

PART 7Alternative Fat Tests for Overall and Specific Migration

1.  Subject to paragraph 2 of this Part the conditions which must be fulfilled to allow the result of either test specified in paragraph 3 be used as an alternative to the result of a migration test carried out under Part 3 are that–

(a)the result obtained in a “comparison test” shows that the values are equal to or greater than those obtained in the test with simulant D; and

(b)the migration occurring in either test specified in paragraph 3 does not, after application of the appropriate reduction factor, exceed the appropriate migration limit.

2.  The condition in paragraph 1(a) does not have to be fulfilled if it can be shown on the basis of the result of scientific experiment that the values obtained in either of the tests specified in paragraph 3 are equal to or greater than those obtained in any of the migration tests specified in Part 3.

3.  The migration tests referred to in paragraphs 2 and 3 are–

(a)a test carried out using volatile media including isooctane, ethanol 95%, other volatile solvents or a mixture of solvents at such contact conditions as would result in values equal to or greater than those obtained in a test using simulant D;